Setting a Pressure Tank’s Air Charge: The 2 PSI Rule Is a Minimum, Not a Target
Set the pre-charge below your pressure switch’s cut-in — 28 psi for a 30/50 switch, 38 for a…
Every published troubleshooting guide, buying guide and how-to in this category, newest first.
Set the pre-charge below your pressure switch’s cut-in — 28 psi for a 30/50 switch, 38 for a…
Close every valve in the house, let the pump run, and watch the gauge. If the pressure climbs…
Your tank’s drawdown in gallons must be at least your pump’s flow in GPM. That single rule decides…
Pick the flow first, then buy horsepower to reach your depth. On every established brand the model number…
Buy on gallons per minute at your own cut-out pressure, not on horsepower. Every listing prints one flow…
“Resetting the well pump” means three unrelated things, and only one of them involves a lever: the breaker…
A click is a contact closing. Something is being told to start and is not starting. And the…
A well pump is sized on two numbers: the flow it must deliver in gallons per minute, and…
Pressure and flow are two different faults and almost every article on this subject treats them as one.…
Everyone gives the same advice: open every tap, highest first, and run the air out. That is half…