The best pitless adapter is the one that fits your well casing, supports the installed drop pipe and pump, and has the correct mating parts. For an existing well, identifying the old adapter comes first. A new adapter with the same pipe size may still be incompatible with the fitting already inside the casing.
This is a comparison of five documented options, not a hands-on durability test. Final selection belongs with the well contractor who can check the casing and suspended load.

Which pitless adapters are worth comparing?
The table uses model-specific manufacturer documentation. Dimensions are nominal connection sizes, not a guarantee that two products will interchange.
| Product | Documented construction and size | Most useful reason to consider it | Main limitation |
|---|---|---|---|
| Boshart PA-100NL | No-lead bronze; 1-inch connection | A documented standard bronze option for a compatible installation | Does not share replacement parts with the P-100 family |
| Boshart P-100-SS | 304 stainless steel; 1-inch connection | A stainless option with a published dimensional and load table | Matching pipe size alone does not establish retrofit fit |
| Boshart Sealwell P-100NL | No-lead bronze; 1-inch connection | Relevant when servicing the older P-100 family | It is not the PA-100NL despite the similar name |
| Merrill SSMB200 | 304 stainless steel; 1-inch drop and discharge | A documented option for a 5–8-inch casing range | Its selection table must be read for the exact variant |
| Simmons 1840SB | Bronze; 1-inch connection | A bronze alternative from another manufacturer | The casing opening must match its installation dimensions |
Sources: [Boshart catalog][1], [Merrill specification][2], and [Simmons product information][3]. These are selection candidates; confirm current supply and the latest installation sheet before ordering.
Boshart PA-100NL: a straightforward bronze candidate
This is worth putting on the contractor’s shortlist when a complete new adapter is being selected. The catalog gives the installer a defined casing range, hole size and supported-load limit rather than only a pipe size.
Its drawback appears during repairs: a homeowner can easily confuse its name with the P-100NL. Ordering by a photograph or a shortened invoice description invites a mismatch. Keep the entire model designation on the purchase order.
Boshart P-100-SS: a stainless option with documented limits
The published catalog lists a 6,000-pound maximum load for this model. That is a component rating, not permission to suspend any pump assembly from any casing. The casing condition, installation and complete suspended assembly still need evaluation.
Choose it when the contractor has a reason to specify this material and has checked the installation. Do not treat stainless construction as proof that all gaskets, mating parts or water conditions are interchangeable.
Boshart Sealwell P-100NL: identify the family first
Boshart identifies P-100NL as the no-lead successor to the discontinued P-100. Its support page distinguishes the removable-joint O-ring from the casing gasket kit and explicitly excludes interchangeability with PA-series repair parts.[4]
That makes the family identification useful even when you ultimately need a seal instead of a complete adapter. It does not establish that every older installation can accept a new assembly without inspection.
Merrill SSMB200: check the actual row in the table
Merrill lists a 1¾-inch hole-saw size and replacement male O-ring OR326 for the SSMB200. The same sheet contains nearby models with different identifiers and dimensions.[2]
The benefit is traceability: the contractor can record the exact row and future repair part. The drawback is that a family-level online listing may display several variants together. Ask for the ordered model on the invoice, not simply “stainless pitless adapter.”
Simmons 1840SB: another bronze option, not a universal insert
Simmons lists this model with a 1-inch connection and describes the family as bronze with a Buna-N O-ring and a position indicator.[3] It is a reasonable comparison candidate when a complete installation is being specified.
Its limitation is the same one that defeats many apparent bargains: a matching outlet diameter does not establish compatibility with the existing casing penetration or removable fitting. Have the installer confirm the drawing before purchase.
Can you replace just the O-ring instead?
Sometimes. The leak location decides whether that is sensible. The removable connection and the casing-wall penetration are different joints. A repair aimed at one does not automatically repair the other.
Start with pitless-adapter leak diagnosis before buying a whole assembly. Ask the contractor to identify the leaking joint, the casting and the correct service part. Do not pull the drop pipe merely to see what fits.
If the well still has a pit rather than an adapter, what collects in that pit is the reason the pitless design exists.
Does a higher load rating make an adapter better?
Only if the rating answers a real requirement. Pressure containment, suspended load and casing fit are separate checks. A larger value in one column cannot make up for a mismatch in another.
The suspended load includes more than the pump itself. The drop-pipe and joint discussion explains why the pipe assembly deserves attention alongside the fitting. Have the contractor calculate the load using the actual pipe material, depth and water-filled assembly.
What should be on the order before you approve it?
Record the complete adapter model, connection size, casing dimensions, required opening and specified repair parts. For an existing well, also record whether the job is replacing the whole adapter or only the removable section or seal.
Current catalog presence is useful evidence that a product is offered; it is not a delivery promise. This review checked manufacturer listings on October 25, 2026. Obtain confirmation of the exact variant and supply before scheduling excavation or a pump pull.
When this needs a pro
The selection measurements can be discussed at the kitchen table. Pulling the pump, supporting the drop pipe, opening the well and altering a buried connection are well-service work. A damaged casing or an unidentified mating part is a reason to stop and investigate, not to force the closest-looking replacement into place.
[1]: https://boshart.com/wp-content/uploads/product-assets/7366e2d999dcb1201e91ed3920accbe53ab8d7ed_Section_11___USA.pdf [2]: https://merrillmfg.com/cdn/shop/files/SSMB_SpecSheet_v1_042025.pdf?v=29787065566347662 [3]: https://www.simmonsmfg.com/pitless-adapter-1/pitless-adapter [4]: https://support.boshart.com/p-100-and-p-100nl-pitless-adapter-replacement-parts