The destination is right and the connection is wrong. Softener brine does belong on the sanitary side, and a sewage ejector basin is the sanitary side. But the drain hose does not go through the lid to get there.
It goes into a trapped, vented receptor with an open rim — a laundry tub, a properly trapped standpipe, a floor drain — across an air gap. That receptor then drains to the basin as ordinary sanitary drainage.
The softener never connects to the pit. It connects to something that does. That one sentence is the whole answer, and it is the opposite of how the question is usually asked.
What the code asks for, and what a basin cannot give

From the Uniform Plumbing Code, 2015 edition, section 801.2:
“Indirect waste piping shall discharge into the building drainage system through an air gap or air break as set forth in this code.”
And the gap has a defined size and a defined reference point. The minimum vertical distance is “not less than 1 inch (25.4 mm)”, measured “from the lowest point of the indirect waste pipe or the fixture outlet to the flood-level rim of the receptor.”
Read that reference point carefully, because it decides everything. A flood-level rim is the edge water would spill over if the receptor filled. A sink has one. A standpipe has one. A floor drain has one.
An ejector basin does not. Its defining feature is a gas-tight cover — there is no open surface and no rim, which is exactly the point of it.
So the hose cannot terminate over the basin, because there is nothing to measure the gap to.
One-minute check on an existing installation: follow the softener’s drain hose with your eyes. If it disappears into the ejector lid, through a grommet or a drilled hole, that is the arrangement to change. If it ends in open air an inch or two above the rim of a tub or a standpipe, it is already right.
Why this answer differs from the dehumidifier one
The site has the neighbouring question on record and it comes out the other way, which is worth understanding rather than memorising.
A dehumidifier cannot discharge into an ejector pit at all. Its output is clear-water waste, and the two ways of getting it into the basin both fail: through the lid is a direct connection with the gas seal broken, and leaving the lid off to create a rim means an open sewage pit in a basement.
For a softener, only the second half of that problem applies. The brine genuinely belongs in the sanitary drainage system — so the destination is not in question, only the route. And unlike the dehumidifier case, there is an ordinary route available: any receptor already draining to that basin.
The distinction is not about which appliance is dirtier. It is that one appliance had nowhere legitimate to send its water in that basement, and the other one does.
On a sewer, the brine passes straight through the plant
This is the fact that reframes the question, and it is not about your pump at all.
From the Minnesota Pollution Control Agency, December 2018:
“Once chloride is dissolved in water, it cannot be removed by settling, or biologically degraded by standard treatment processes. The technology to remove chloride is available, but is costly. It would involve microfiltration and reverse osmosis.”
“Treatment facilities are designed to remove particles, like grit and sand, and to biologically degrade organic waste, such as food and human waste.”
Everything else a house sends down that basin is something a treatment plant is built to handle. Solids settle. Organics are digested. Chloride arrives and leaves unchanged.
It is enough of a problem to be tracked. The same agency reports that chloride in wastewater discharge “appears to be a problem in about 100 Minnesota communities”, against that state’s 230 mg/L Class 2B chloride standard.
That is Minnesota’s number and Minnesota’s count, quoted because the agency publishes both plainly — not because they govern your town. Some municipalities restrict softener discharge to the sewer and some do not, and that is a local question.
On septic, the health department is calmer than the internet
If the ejector basin discharges to a septic system rather than a sewer, the picture changes — and the official position is more measured than most of what is written about it.
From the New York State Department of Health’s design handbook for residential onsite wastewater treatment systems:
“Water softening or other water conditioning equipment discharges are often directed to the OWTS through the household plumbing. In the majority of these cases, no problems are indicated with the OWTS.“
Then the two conditions that change it, both named:
“Waste brine from household water softener units may have an adverse effect on the operation of a septic tank when the water treatment system is not operating properly and may cause a shortening of the life of an absorption facility, particularly when the system is installed in a structured clay type soil.”
A malfunctioning softener, and clay. Those are checkable things, and neither is “you have a water softener.”
The preference, where it is practical:
“Therefore, when possible, brine backwash waste from household water softening equipment should be discharged to a separate soil absorption facility such as a trench or shallow pit.”
And one hard prohibition:
“Discharging brine backwash waste from household water softening equipment directly into the groundwater or on the surface of the ground is unacceptable.”
Which rules out the fix people reach for first — running the hose outside.
This is the same trade-off the site has already worked through from the other direction. Sending clear water into a septic system is a volume problem rather than a chemistry one; brine is the reverse — a small volume that matters because of what is in it.
And the sump version of this question has a different answer again
Worth saying plainly, because people arrive here having read the wrong one.
A softener must not discharge into a sump pit — a sump sends its water to daylight, to a storm drain or to the ground, which is the one place brine must not go, and that page quotes a city ordinance saying so.
An ejector basin is the opposite machine. It sends its water to the sanitary system. Same house, same appliance, two pits, opposite verdicts — and the difference is entirely where each pit’s discharge ends up.
The one thing you can change without a plumber
It is a setting, and it comes from the same health department document:
“An as-needed regeneration softener is recommended over an automatic timer-operated softener to minimize the number of regeneration brine discharges.”
“A water softener should be set to reflect the actual hardness, manganese or iron level(s) in the dwelling’s water supply.”
A timer-operated softener regenerates on a schedule whether it needs to or not. A demand-initiated one regenerates when the resin is actually exhausted. Fewer cycles, less brine, same soft water — and on an older unit this is often the single biggest change available.
Pro note: the hardness setting is the other half of it. A unit set richer than the water requires regenerates more often than it needs to for the life of the softener, and that setting is frequently left wherever the installer put it on day one.
What this does not change about the pump
Nothing here is a reason to pick a different ejector pump, and nothing here diagnoses one that is misbehaving.
If the basin is already taking softener discharge through a correct receptor, the extra water is a small, infrequent slug on a pump sized for a bathroom. If you are replacing the pump for other reasons, the specs that actually separate them are a different question entirely — and flow at a stated height is the one that matters, not the number on the box.
When this needs a pro
Changing where the drain hose terminates. It sounds like moving a hose and it is a drainage alteration, with an air gap dimension and a receptor that has to be trapped and vented.
Anything that involves opening the ejector lid. The seal is the only thing between the basement and sewer gas, and a grommet in it is not a repair.
Deciding whether your jurisdiction allows it at all. Softener discharge rules vary more than most plumbing rules — some places route brine to the sanitary sewer by default, some restrict it, and some require a separate absorption facility.
Anything on a septic system. The tank and the field are the parts you cannot easily replace, and the handbook’s two conditions — a softener that is not working properly, and clay soil — are both things to have assessed rather than guessed.
What you can do yourself: follow the hose and see where it ends, find out whether your basin goes to a sewer or a septic tank, and check whether your softener regenerates on a timer or on demand. Three things, no tools — and they decide whether anything needs doing at all.
FAQ
Can a water softener drain into a sewage ejector pit?
The brine belongs on the sanitary side, so the basin is the right destination — but the hose must not be run into the pit itself. It discharges across an air gap into a trapped, vented receptor such as a laundry tub, standpipe or floor drain, which then drains to the basin.
Why can’t the softener hose go straight into the ejector lid?
Two reasons. The code requires an indirect connection with an air gap measured to the flood-level rim of a receptor, and a gas-tight basin has no rim to measure to. And the lid’s seal is what keeps sewer gas out of the basement, so putting a hose through it defeats the part that matters most.
Will softener brine damage my sewage ejector pump?
That is not where the published concern sits. The agencies that write about this are concerned with where the chloride ends up — a treatment plant that cannot remove it, or a septic field — rather than with the pump. The volume reaching the basin is small and infrequent compared with normal fixture use.
Is softener discharge bad for a septic system?
Less than is usually claimed. A state health department’s position is that in the majority of cases no problems are indicated, with two specific conditions that change it: a softener that is not operating properly, and an absorption field in structured clay soil. Where practical, it recommends a separate soil absorption facility.
Can I just run the softener drain outside instead?
No. The same handbook calls discharging brine backwash directly into the groundwater or onto the surface of the ground unacceptable. It is the fix people reach for first and it is the one explicitly ruled out.
How do I reduce how much brine goes down the drain?
Two settings. A demand-initiated softener that regenerates when the resin is actually exhausted is recommended over a timer-operated one that regenerates on a schedule, and the unit should be set to the water’s actual measured hardness rather than left where it was delivered.